Microbiol Spectr ; 9(1): e0034221, 2021 09 03.
Artigo em Inglês | MEDLINE | ID: mdl-34346748

RESUMO

As the COVID-19 pandemic progresses, there is an increasing need for rapid, accessible assays for SARS-CoV-2 detection. We present a clinical evaluation and real-world implementation of the INDICAID COVID-19 rapid antigen test (INDICAID rapid test). A multisite clinical evaluation of the INDICAID rapid test using prospectively collected nasal (bilateral anterior) swab samples from symptomatic subjects was performed. The INDICAID rapid test demonstrated a positive percent agreement (PPA) and negative percent agreement (NPA) of 85.3% (95% confidence interval [95% CI], 75.6% to 91.6%) and 94.9% (95% CI, 91.6% to 96.9%), respectively, compared to laboratory-based reverse transcriptase PCR (RT-PCR) using nasal specimens. The INDICAID rapid test was then implemented at COVID-19 outbreak screening centers in Hong Kong as part of a testing algorithm (termed "dual-track") to screen asymptomatic individuals for prioritization for confirmatory RT-PCR testing. In one approach, preliminary positive INDICAID rapid test results triggered expedited processing for laboratory-based RT-PCR, reducing the average time to confirmatory result from 10.85 h to 7.0 h. In a second approach, preliminary positive results triggered subsequent testing with an onsite rapid RT-PCR, reducing the average time to confirmatory result to 0.84 h. In 22,994 asymptomatic patients, the INDICAID rapid test demonstrated a PPA of 84.2% (95% CI, 69.6% to 92.6%) and an NPA of 99.9% (95% CI, 99.9% to 100%) compared to laboratory-based RT-PCR using combined nasal/oropharyngeal specimens. The INDICAID rapid test has excellent performance compared to laboratory-based RT-PCR testing and, when used in tandem with RT-PCR, reduces the time to confirmatory positive result. IMPORTANCE Laboratory-based RT-PCR, the current gold standard for COVID-19 testing, can require a turnaround time of 24 to 48 h from sample collection to result. The delayed time to result limits the effectiveness of centralized RT-PCR testing to reduce transmission and stem potential outbreaks. To address this, we conducted a thorough evaluation of the INDICAID COVID-19 rapid antigen test, a 20-minute rapid antigen test, in both symptomatic and asymptomatic populations. The INDICAID rapid test demonstrated high sensitivity and specificity with RT-PCR as the comparator method. A dual-track testing algorithm was also evaluated utilizing the INDICAID rapid test to screen for preliminary positive patients, whose samples were then prioritized for RT-PCR testing. The dual-track method demonstrated significant improvements in expediting the reporting of positive RT-PCR test results compared to standard RT-PCR testing without prioritization, offering an improved strategy for community testing and controlling SARS-CoV-2 outbreaks.


Assuntos
Antígenos Virais/análise , Doenças Assintomáticas , Teste para COVID-19/métodos , COVID-19/diagnóstico , COVID-19/imunologia , SARS-CoV-2/isolamento & purificação , Adulto , Técnicas de Laboratório Clínico/métodos , Reações Falso-Negativas , Reações Falso-Positivas , Feminino , Hong Kong , Humanos , Masculino , Programas de Rastreamento/métodos , Pessoa de Meia-Idade , Pandemias , Reação em Cadeia da Polimerase , SARS-CoV-2/genética , Sensibilidade e Especificidade , Manejo de Espécimes , Fatores de Tempo , Adulto Jovem
2.
Clin Breast Cancer ; 20(3): 253-261.e7, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32205037

RESUMO

BACKGROUND: In addition to TNM-based anatomical staging (AS), a novel pathological prognostic staging (PPS) has been proposed by the American Joint Committee on Cancer (AJCC). PPS demonstrated better prognostication, but its superiority in breast cancer subtypes and related to staging discrepancies between AS and PPS are not clear. METHODS: A cohort of 1729 patients with breast cancer was staged into AS and PPS according to the latest AJCC staging. Patient characteristic and restaging outcomes were compared. RESULTS: Compared with AS, 799 and 135 cases were upstaged and downstaged respectively in PPS, mostly involved stage I cases. For the overall cohort, PPS demonstrated superior prognostic power over AS in both disease-free survival (DFS) and breast cancer-specific survival. However, such superiority was found mainly in estrogen receptor (ER)/progesterone receptor (PR)+ but not ER-PR- cancers. Comparing the restaged cases within the same PPS, PPS 1A cases showed similar survival irrespective of the original AS. Interestingly, in other PPS groups (PPS 1B and higher), there was a difference in outcome among patients with same PPS but different AS. Within PPS 1B patients, downstaged cases from higher AS showed worse DFS (3A>1B vs. 2A>1B: χ2 = 4.732, P = .030). CONCLUSIONS: PPS may provide a more accurate prognostication, mostly among ER/PR+ cancers and with PPS 1A patients. Patients restaged to higher PPS stages showed significant differential survival even within the same PPS. Also, only limited improvement was observed for ER-PR- cancers. Caution needs to be exercised in using PPS for patient prognostication, as in some cases the outcome can be variable with the same PPS.


Assuntos
Biomarcadores Tumorais/análise , Neoplasias da Mama/diagnóstico , Mama/patologia , Recidiva Local de Neoplasia/epidemiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Protocolos de Quimioterapia Combinada Antineoplásica , Biomarcadores Tumorais/metabolismo , Mama/cirurgia , Neoplasias da Mama/mortalidade , Neoplasias da Mama/patologia , Neoplasias da Mama/terapia , Quimioterapia Adjuvante/métodos , Quimioterapia Adjuvante/estatística & dados numéricos , Intervalo Livre de Doença , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Mastectomia , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/patologia , Recidiva Local de Neoplasia/prevenção & controle , Estadiamento de Neoplasias , Prognóstico , Receptor ErbB-2/análise , Receptor ErbB-2/metabolismo , Receptores de Estrogênio/análise , Receptores de Estrogênio/metabolismo , Receptores de Progesterona/análise , Receptores de Progesterona/metabolismo , Medição de Risco/métodos , Adulto Jovem
3.
Sci Rep ; 7: 41836, 2017 02 07.
Artigo em Inglês | MEDLINE | ID: mdl-28169331

RESUMO

The performance of a room temperature, zero-field MASER operating at 1.45 GHz has been examined. Nanosecond laser pulses, which are essentially instantaneous on the timescale of the spin dynamics, allow the visible-to-microwave conversion efficiency and temporal response of the MASER to be measured as a function of excitation energy. It is observed that the timing and amplitude of the MASER output pulse are correlated with the laser excitation energy: at higher laser energy, the microwave pulses have larger amplitude and appear after shorter delay than those recorded at lower laser energy. Seeding experiments demonstrate that the output variation may be stabilized by an external source and establish the minimum seeding power required. The dynamics of the MASER emission may be modeled by a pair of first order, non-linear differential equations, derived from the Lotka-Volterra model (Predator-Prey), where by the microwave mode of the resonator is the predator and the spin polarization in the triplet state of pentacene is the prey. Simulations allowed the Einstein coefficient of stimulated emission, the spin-lattice relaxation and the number of triplets contributing to the MASER emission to be estimated. These are essential parameters for the rational improvement of a MASER based on a spin-polarized triplet molecule.

4.
Appl Magn Reson ; 46(4): 359-368, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25798030

RESUMO

Pulsed electron paramagnetic resonance (EPR) spectroscopy using microwaves at two frequencies can be employed to measure distances between pairs of paramagnets separated by up to 10 nm. The method, combined with site-directed mutagenesis, has become increasingly popular in structural biology for both its selectivity and capability of providing information not accessible through more standard methods such as nuclear magnetic resonance and X-ray crystallography. Despite these advantages, EPR distance measurements suffer from poor sensitivity. One contributing factor is technical: since 65 MHz typically separates the pump and detection frequencies, they cannot both be located at the center of the pseudo-Lorentzian microwave resonance of a single-mode resonator. To maximize the inversion efficiency, the pump pulse is usually placed at the center of the resonance, while the observer frequency is placed in the wing, with consequent reduction in sensitivity. Here, we consider an alternative configuration: by spacing pump and observer frequencies symmetrically with respect to the microwave resonance and by increasing the quality factor, valuable improvement in the signal-to-noise ratio can be obtained.